nomenclat. № name length diameter weight class pressure
m /pc. m. /pc. t. /pc. P razr.
10100100 Reinforced Concrete Coupling Drain Pipe Ф 300 x 2500, d = 75 2.50 0.30 0.592 1 48.00
10100300 Reinforced Concrete Coupling Drain Pipe Ф 500 x 2500, d = 80 2.50 0.50 0.930 1 45.00
10100200 Reinforced Concrete Coupling Drain Pipe Ф 400 x 2500, d = 80 2.50 0.40 0.803 1 53.00
10100400 Reinforced Concrete Coupling Drain Pipe Ф 600 x 2500, d = 85 2.50 0.60 1.318 1 45.00
10100500 Reinforced Concrete Coupling Drain Pipe Ф 800 x 2500, d = 94 2.50 0.80 2.006 1 51.00
10100600 Reinforced Concrete Coupling Drain Pipe Ф 1000 x 2500, d = 124 with fitting anchors 2.50 1.00 3.147 1 53.00
10100700 Reinforced Concrete Coupling Drain Pipe Ф 1200 x 2500, d = 139 with fitting anchors 2.50 1.20 4.308 1 51.00

REINFORCED CONCRETE COUPLING DRAIN PIPES WITH INTEGRATED SEAL L = 2.5 m 1. Application: The preliminary casted reinforced concrete coupling pipes with integrated flexible seal are designed for the construction of drainage and sewerage non-pressure and low-pressure systems for transfer of sewer, rain and treated industrial wastewater. 2. Design: The use and laying of the pipes at each site shall be performed according to an investment project, developed and approved in the respective legal manner, while observing the current construction and normative documents. 3. Laying: The pipes are laid on a preliminary made sand cushion or casted blinding concrete B 15, and the obtained angle shall be between 90° and 120°. The pipes are stuck into each other through sliding. The areas where the seals are located shall be cleaned before assembly. The sliding grease is placed at the pipe end where there is no seal, i.e. on the concrete. The pipe coupling starts from the endmost, deepest part of the pipeline. Each pipe, especially the first one, shall be well centered and the sliding power shall be carefully controlled. Each of the next pipes that will be slid in the previous pipe shall be lifted and it shall hang freely. In order to prevent the damage of the elastomeric seals, special devices shall be used. The pipe sliding with an excavator will damage them. The distance between the ends of two pipes shall be at least 5 mm. In general, the wastewater pipes shall be connected in a straight line between two shaft structures. The direction change, if necessary, shall be implemented from the shaft structures. It is possible to have curves along the path through preliminary casted curved articles. The pipe design position shall be geodetically controlled. 4. Use and maintenance: The designed life of the pipes manufactured according to this standard is very long. No special maintenance is required during the operation period.

concrete coupling drain pipes with integrated seal, L = 2.5 m –pressureless BDS EN 1916; BDS EN 681-1

spacer
2008-08-22-16-29-26-product_image_1-m1.jpg
zoom
nomenclat. № name length diameter weight pressure
m /pc. m. /pc. t. /pc. P razr.
11100300 Concrete Coupling Drain Pipe Ф 500 x 2500, d = 80 2.50 0.50 0.880 40.00
11100200 Concrete Coupling Drain Pipe Ф 400 x 2500, d = 80 2.50 0.40 0.755 43.00
11100100 Concrete Coupling Drain Pipe Ф 300 x 2500, d = 75 2.50 0.30 0.548 40.00
11100400 Concrete Coupling Drain Pipe Ф 600 x 2500, d = 85 2.50 0.60 1.242 40.00
11100500 Concrete Coupling Drain Pipe Ф 800 x 2500, d = 94 2.50 0.80 1.860 41.00
11100600 Concrete Coupling Drain Pipe Ф 1000 x 2500, d = 124 with fitting anchors 2.50 1.00 3.099 48.00
11100700 Concrete Coupling Drain Pipe Ф 1200 x 2500, d = 139 with fitting anchors 2.50 1.20 4.131 48.00

CONCRETE COUPLING DRAIN PIPES WITH INTEGRATED SEAL L = 2.5 m 1. Application: The preliminary casted concrete coupling drain pipes with integrated flexible seal are designed for the construction of drainage and sewerage non-pressure and low-pressure systems for transfer of sewer, rain and treated industrial waste water. 2. Design: The use and laying of the pipes at each site shall be performed according to an investment project, developed and approved in the respective legal manner, while observing the current construction and normative documents. 3. Laying: The pipes are laid on a preliminary made sand cushion or casted blinding concrete B 15, and the received angle shall be between 90° and 120°. The pipes are stuck into each other through sliding. The areas where the seals are located shall be cleaned before assembly. The sliding grease is placed at the pipe end where there is no seal, i.e. on the concrete. The pipe coupling starts from the endmost, deepest part of the pipeline. Each pipe, especially the first one, shall be well centered and the sliding power shall be carefully controlled. Each of the next pipes that will be slid in the previous pipe shall be lifted and it shall hang freely. In order to prevent the damage of the elastomeric seals, special devices shall be used. The pipe sliding with an excavator will damage them. The distance between the ends of two pipes shall be at least 5 mm. In general, the wastewater pipes shall be connected in a straight line between two shaft structures. The direction change, if necessary, shall be implemented from the shaft structures. It is possible to have curves along the path through preliminary casted curved articles. The pipe design position shall be geodetically controlled. 4. Use and maintenance: The designed life of the pipes produced according to this standard is very long. No special maintenance is required during their operation period.

reinforced concrete coupling drain pipes, double reinforcement, for road and railway culverts BDS EN 1916

spacer
nomenclat. № name length diameter weight pressure
m /pc. m. /pc. t. /pc. P razr.

drain pipes

spacer

rabbet pipes

spacer

reinforced concrete rabbet pipes, double reinforcement for sewerage, railway and road culverts

spacer
nomenclat. № name length diameter weight pressure
m /pc. m. /pc. t. /pc. P razr.
11041000 Reinforced Concrete Rabbet Pipe T 150 x 12 x 200 2.00 1.50 3.098 95.00
11043000 Reinforced Concrete Rabbet Pipe T 50 x 8 x 250 2.50 0.50 0.981 55.00
11045000 Reinforced Concrete Rabbet Pipe T 80 x 9.4 x 250 2.50 0.80 2.072 71.00
11047000 Reinforced Concrete Rabbet Pipe T 100 x 12.4 x 250 2.50 1.00 3.481 78.00
11048000 Reinforced Concrete Rabbet Pipe T 40 x 8 x 250 2.50 0.40 0.803 51.00
11049000 Reinforced Concrete Rabbet Pipe T 60 x 8.5 x 250 2.50 0.60 1.318 68.00
11050000 Reinforced Concrete Rabbet Pipe T 120 x 13.9 x 250 2.50 1.20 4.308 95.00
11010400АА Reinforced Concrete Rabbet Pipe Т 40 х 4,5 х 100 1.00 0.40 0.206 51.00
11010500АА Reinforced Concrete Rabbet Pipe Т 50 х 5,5 х 100 1.00 0.50 0.300 55.00
11010600АА Reinforced Concrete Rabbet Pipe Т 60 х 6,5 х 100 1.00 0.60 0.427 68.00
11010700АА Reinforced Concrete Rabbet Pipe Т 80 х 8,5 х 100 1.00 0.80 0.614 71.00
11010800АА Reinforced Concrete Rabbet Pipe Т 100 х 9,5 х 100 1.00 1.00 0.886 78.00
10100800АА Reinforced Concrete Rabbet Pipe Т 140 х 16 х 250 2.50 1.40 5.279 95.00
11010900АА Reinforced Concrete Rabbet Pipe Т 150 х 9,5 х 100 1.00 1.50 1.446 95.00
10100900АА Reinforced Concrete Rabbet Pipe Т 160 х 17 х 250 2.50 1.60 6.220 95.00
10101000АА Reinforced Concrete Rabbet Pipe Т 180 х 20 х 250 2.50 1.80 7.277 95.00
10101100АА Reinforced Concrete Rabbet Pipe Т 200 х 20 х 250 2.50 2.00 9.059 95.00

1. REINFORCED CONCRETE PIPES, DOUBLE REINFORCEMENT – used for construction of sewerage pipelines, road and railway culverts. 1. Design The use of the manufactured pipes at each specific site is performed according to an investment project, developed and approved in the respective legal manner, while observing the technical construction norms and the requirements of BDS EN 1916. The minimal filling cover above the pipes is 600 mm for the culverts measured from the upper surface of the pipe to the pavement level. When the filling cover is 1500 mm thick, the pipes shall be placed on a sand base course. When the thickness is bigger, a profiled base course of blinding concrete of B 15 class concrete with range angle of 120° and minimal thickness of 20 cm shall be provided. The thickness of the fill shall be no bigger than 3.0 m. 2. Laying The double reinforced concrete pipes are laid in the design position on the preliminary made sand cushion or on casted blinding concrete with minimal thickness of 20 cm. The loading and unloading and the laying operations shall be implemented with a crane with a hoisting capacity and range depending on the specific conditions for G pipe = 3.0 t. The laying is performed by two fitters under the supervision of a responsible supervisor. The staff shall have a 2nd degree fitter qualification. The design position of the pipes shall be geodetically controlled. When there are no fitting anchors, there should be rubber pads to protect the pipe front edges from demolition. 3. Use and maintenance The double reinforced concrete pipes have a long life and no special maintenance is required.

concrete rabbet pipes – without footing (RP) and with footing (RPF), L = 1 m – pressureless BDS 17004; BDS 895

spacer
2008-08-22-16-53-30-product_image_1-11010100.jpg
zoom
nomenclat. № name length diameter weight pressure
m /pc. m. /pc. t. /pc. P razr.
11010100 RP Ф 150 x 1000, d = 30 1.00 0.15 0.041 25.00
11010200 RPF Ф 200 x 1000, d = 30 1.00 0.20 0.062 27.00
11010300 RP Ф 300 x 1000, d = 35 1.00 0.30 0.144 31.00
11011300 RPF Ф 300 x 1000, d = 35 1.00 0.30 0.155 31.00
11010400 RPF Ф 400 x 1000, d = 45 1.00 0.40 0.196 32.00
11010500 RPF Ф 500 x 1000, d = 55 1.00 0.50 0.269 34.00
11010600 RPF Ф 600 x 1000, d = 65 1.00 0.60 0.412 37.00
11010700 RP Ф 800 x 1000, d = 85 1.00 0.80 0.557 42.00
11010800 RP Ф 1000 x 1000, d = 95 1.00 1.00 0.824 48.00
11010900 RP Ф 1500 x 1000, d = 95 1.00 1.50 1.236 53.00

concrete sewerage rabbet pipes /CSRP/, L = 2.5 m – pressureless /for shafts/ BDS EN 1917

spacer
2008-08-22-17-09-30-product_image_1-f.jpg
zoom
2008-08-22-17-09-30-product_image_2-f3.jpg
zoom
nomenclat. № name length diameter weight pressure
m /pc. m. /pc. t. /pc. P razr.
11100900 CSRP Ф 1600 x 2500 with fitting anchors, d = 170 2.50 1.60 5.890 32.00
11100800 CSRP Ф 1400 x 2500 with fitting anchors, d = 160 2.50 1.40 4.963 32.00
11101000 CSRP Ф 1800 x 2500 with fitting anchors, d = 200 2.50 1.80 7.028 39.00
11101100 CSRP Ф 2000 x 2500 with fitting anchors, d = 200 2.50 2.00 8.679 35.00

reinforced concrete sewerage rabbet pipes /RCSRP/, L = 2.5 m – low pressure

spacer
nomenclat. № name length diameter weight class pressure
m /pc. m. /pc. t. /pc. P razr.
10100800 RCSRP Ф 1400 x 2500, d = 160 with fitting anchors 2.50 1.40 5.279 1 75.00
10100900 RCSRP Ф 1600 x 2500, d = 170 with fitting anchors 2.50 1.60 6.220 1 71.00
10101000 RCSRP Ф 1800 x 2500, d = 200 with fitting anchors 2.50 1.80 7.257 1 72.00
10111100 RCSRP Ф 2000 x 2500, d = 200 with fitting anchors 2.50 2.00 9.059 1 80.00

REINFORCED CONCRETE SEWERAGE RABBET PIPES, L = 2.5 m – LOW PRESSURE 1. Application: The preliminary casted reinforced concrete sewerage rabbet pipes with integrated flexible seal are designed for the construction of drainage and sewerage non-pressure and low-pressure systems for transfer of sewer, rain and treated industrial wastewater. 2. Design: The use and laying of the pipes at each site shall be performed according to an investment project, developed and approved in the respective legal manner, while observing the current construction and normative documents. 3. Laying: The pipes are laid on a preliminary made sand cushion or casted blinding concrete B 15, and the obtained angle shall be between 90° and 120°. The pipes are stuck into each other through sliding. The areas where the seals are located shall be cleaned before assembly. The sliding grease is placed at the pipe end where there is no seal, i.e. on the concrete. The pipe coupling starts from the endmost, deepest part of the pipeline. Each pipe, especially the first one, shall be well centered and the sliding power shall be carefully controlled. Each of the next pipes that will be slid in the previous pipe shall be lifted and it shall hang freely. In order to prevent the damage of the elastomeric seals, special devices shall be used. The pipe sliding with an excavator will damage them. The distance between the ends of two pipes shall be at least 5 mm. In general, the wastewater pipes shall be connected in a straight line between two shaft structures. The direction change, if necessary, shall be implemented from the shaft structures. It is possible to have curves along the path through preliminary casted curved articles. The pipe design position shall be geodetically controlled.

seals for reinforced concrete sewerage rabbet pipes, L = 2.5 m – low pressure EN 681-1

spacer
nomenclat. № name diameter
m. /pc.
10130800 Sealing Ф 1400 1.40
10130900 Sealing Ф 1600 1.60
10131000 Sealing Ф 1800 1.80
10131100 Sealing Ф 2000 2.00

Reinforced concrete rabbet pipes, without footing and with footing - L = 1m /2m - non-pressure /RCRP/ BDS 17343; BDS 895

spacer
nomenclat. № name length diameter weight pressure
m /pc. m. /pc. t. /pc. P razr.
11010700А RCRP Ø 800 х 1000 - single reinforcement d=85 1.00 0.80 0.588 45.00
11010700АА RCRP Ø 800 х 1000 - double reinforcement d=85 1.00 0.80 0.630 68.00
11010800А RCRP Ø 1000 х 1000 - single reinforcement d=95 1.00 1.00 0.859 53.00
11010800АА RCRP Ø 1000 х 1000 - double reinforcement d=95 1.00 1.00 0.911 73.00
11010900А RCRP Ø 1500 х 1000 - single reinforcement d=95 1.00 1.50 1.334 70.00
11010900АА RCRP Ø 1500 х 1000 - double reinforcement d=95 1.00 1.50 1.435 95.00
11011000А RCRP Ø 1500 х 2000 - single reinforcement d=120 2.00 1.50 2.875 70.00
11011000АА RCRP Ø 1500 х 2000 - double reinforcement d=120 2.00 1.50 3.075 95.00